Binary Gas Analyzer for Hydrogen Cooled Generators - XTC601 HCG

Updated:2025-03-13

Views:837

  • Brand: PST/Michell
  • Model: XTC601 HCG
  • Description: A multi-map binary gas analyzer designed specifically for the measurement of gas mixes present during the operation and maintenance of hydrogen cooled electricity generators. The primary measurement i
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Binary Gas Analyzer for Hydrogen Cooled Generators - XTC601 HCG Description:

User's Manual Datasheet

Monitoring Gas Mixtures During Maintenance and Operation

Features

Suitable for use in ATEX, UKCA, IECEx, TR CU Ex & cQPSus certified Hazardous Areas

Monitors all three phases of hydrogen cooled electricity generators - normal running, purging and maintenance

Remotely change the measurement phase to match your maintenance schedule

Range indication via 4...20 mA output

Touch-screen display allows calibration or adjustment without the need for a hot works permit

Compact and rugged design with an EExd enclosure

IP66 rated enclosure

Low cost of ownership due to minimal maintenance

A multi-map binary gas analyzer designed specifically for the measurement of gas mixes present during the operation and maintenance of hydrogen cooled electricity generators. The primary measurement is hydrogen (H2) purity, with air as the background gas. The second measurement is monitoring hydrogen in carbon dioxide (CO2) during system purging, and finally carbon dioxide/air during maintenance. The analyzer is suitable for general purpose or hazardous areas and uses non-depleting sensor technology for minimal cost of ownership.

Specifications

Performance
Phase Phase 1 -
H2 in Air
Phase 2 -
H2 in CO2
Phase 3 -
CO2 in Air
Measurement Range 80...100 % or 90...100 % 0...100 % 0...100 %
Display resolution 0.01 % 0.1 % 1 %
Response time (T90) <20 seconds <20 seconds <50 seconds
Recommended calibration Monthly Prior to use Annually
Measurement Technology Thermal Conductivity sensor
Gas Requirements Non-condensing sample with particles <3μm
Display Type Backlit LCD
Repeatability ±0.2 % of range
Linearity ±1 % range
Sample Flow Rate 100...600 ml/min
Sample Flow Effect
(calibrated at 300 ml/min)
< 1 % of range for flows:
100...600 ml/min
Sample Pressure 0...3 barg with atmospheric vent
Sample Temperature 0...+45 °C max
Sample Cell Temperature +50 °C
Electrical Specifications
Analog Inputs 2 off 4...20 mA inputs
One to control phase selection
One for an external sensor that can be displayed on the screen
Analog Outputs 2 off 4...20 mA outputs:
mA 1 = Concentration
mA 2 = Phase indication
Alarms 2 off single pole changeover (SPCO) relays (250 V, 5 A max)
Digital Communications Modbus RTU over RS485
Power Supply 24 V DC; 1.5 A max
Operating Conditions
Ambient Temperature -15...+55 °C
Mechanical Specifications
Warm Up and Stabilization Time < 30 minutes
Dimensions 234 x 234 x 172mm (w x d x h)
Weight 9.7kg
Wetted Materials 316 stainless steel, boroscillicate glass, platinum, Viton
O-Ring Materials Viton
Gas Connection 1/8” NPT
Ingress Protection IP66, NEMA 4
Hazardous Area Classification
ATEX/UKCA II 2GD Ex d IIB +H2 T6 Gb
Ex tb IIIC T85 °C Db IP66
-15 °C...+55 °C
IECEx Ex d IIB +H2 T6 Gb
Ex tb IIIC T85 °C Db IP66
-15 °C...+55 °C
cQPSus Class I, Division 1, Groups B,C,D T6C
TR CU 1Exd IIB+H2 T6 Gb

Suitable Applications

Measuring the binary gas mixes present during the operation and maintenance of hydrogen cooled electricity generators

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796