国产精品三级-日韩中文字幕在线播放-欧美色图88-爱福利视频网-美女视频黄免费-青青草视频在线观看免费-国产主播一区二区-久久理论电影-污污网站在线-国产精品12-99精品在线观看视频-丁香啪啪-国产成人精品免高潮在线观看-日韩高清在线一区-久久久久毛片-91精品国产91久久久久久-美女扒开腿让男生桶-91性生活-91黑丝美女-91大神久久

Products

current position:home page>Products>Analysis Instrument>PST>

Michell Intrinsically Safe Field Display

Updated:2025-03-13

Views:895

  • Brand: PST/Michell
  • Model: Michell
  • Description: The Intrinsically Safe Field Display is a 4-digit loop-powered local monitor for the Easidew PRO I.S. and Easidew I.S. transmitters. It is certified with ATEX, IECEx, UKCA and FM and housed in an IP66
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Michell Intrinsically Safe Field Display Description:

Product Manual

For Use with Easidew I.S. and Easidew PRO I.S.

Features

Loop powered 4-20mA indicator. Intrinsically safe certified with ATEX, IECEx, UKCA and FM

Operating temperature between -40 and +70°C

Bold 34mm high 4-digit display with optional backlight

Robust GRP enclosure providing IP66 protection. Can be mounted by itself or inside a sampling system enclosure

Built-in terminal compartment for easy wiring

Two optional galvanically isolated solid-state alarm outputs

The Intrinsically Safe Field Display is a 4-digit loop-powered local monitor for the Easidew PRO I.S. and Easidew I.S. transmitters. It is certified with ATEX, IECEx, UKCA and FM and housed in an IP66 enclosure with a terminal compartment for wiring. The measurement unit can be labelled as ppmV, ppm W, °C dp or °F dp.

Specification

Input
Current (dp) 4 to 20mA
Voltage drop Less than 1.2V at 20°C
Less than 1.3V at –40°C
Less than 5V with optional loop powered
backlight
Display
Type Liquid crystal, non-multiplexed 4 digits 34mm high
Resolution Dewpoint
   0.1 °C/°F
ppmV / ppmW
   1 for 1000 – 9999
   0.1 for 100.0 – 999.9
   0.01 for 10.00 – 99.99
   0.001 for 0.000 – 9.999
Span Adjustable between 0 & ±9999 with 20mA input
Zero Adjustable between 0 & ±9999 with 4mA input
Over-Range/Under-Range 9999 or –9999 with all decimal points flashing
Certification (Display Only)
ATEX/UKCA Group II Category 1GD
Ex ia IIC T5 Ga
Ta = -40 to +70°C
IECEx Ex ia IIC T5 Ga
Tamb = -40 to 70°C
FM CL I, II, III: Div 1: GP A, B, C, D, E, F & G
T4 @ 70°C
Environmental
Operating Temperature -40 to +70°C (-20 to +60°C for FM version)
Storage Temperature -40 to +85°C
Humidity To 95% at 40°C non-condensing
Enclosure IP66
Mechanical
Terminals (dp) Screw clamp for 0.5 to 1.5mm2 conductors
Weight 1.7kg
Accessories
Backlight Green, loop powered. Voltage drop of indicator plus backlight less than 5V
Alarms Two alarm outputs each of which may be independently configured. Isolated solid state switch complying with requirements for simple apparatus
Ron 5Ω + 0.7V max
Roff 1MΩ min
External Keypad Membrane keypad enables indicator to be configured without removing cover
Stainless Steel Legend Plate Etched legend plate with tag number or application attached to front of the instrument
Pipe Mount Kit Stainless steel bracket secured by two stainless steel worm drive hose clips for 60 to 80mm (outside diameter) vertical or horizontal pipe