Dew-Point Calibration System - Michell DCS

Updated:2025-03-13

Views:835

  • Brand: PST/Michell
  • Model: DCS
  • Description: The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Dew-Point Calibration System - Michell DCS Description:

Datasheet

All-in-One Configurable Calibration Station

Features

Complete dew-point calibration solution with optional compressor, dryer, dew-point generator, reference instrument and optional manifold

Generated output responds quickly to a change of set point

Stable humidity generation

Simple operation through manual flow mixing or push-button switching of set points

Remote control via RS232/USB comms (dependant on model)

The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through customization the DCS system can be PC controlled for automated calibration sequences or manually operated at pre-determined dew-point set points.

Specifications

Model DCS60 DCS80 DCS100
Range -60 to +20°Cdp (-76 to +68°Fdp) -80 to +20°Cdp (-112 to +68°Fdp) -100 to +20°Cdp (-148 to +68°Fdp)
Air Dryer PSD2 Dryer PSD4 Super Dryer
Generator Method DG2 with manual flow metering
ADG400 with mass flow controllers
VDS system with mass flow controllers
Reference Hygrometer S8000 Chilled Mirror Hygrometer S8000RS Chilled Mirror Hygrometer S8000 -100 Chilled Mirror Hygrometer
Calibration Flow Rate 2 to 5 Nl/min (4.2 to 10.6 scfh) 10 Nl/min (21.2 scfh)
Best System Uncertainty ±0.2°C (±0.36°F) dew point (k = 2) @ +20°Cdp (+68°Fdp)
Set Point Precision ±0.5°C (±0.9°F) dew point
Carrier Gas Oil-free compressed air (compressor supplied)
Operating Temperature +15 to +30°C (+59 to +86°F)
Traceability Directly to NPL and NIST through Reference Hygrometer
Power 220 to 240 V AC or 100 to 130 V DC, 50/60 Hz
Housing Wheeled 19" rack system, 1.9m (74.8") high
Weight 98kg (216lbs) (approx) 125kg (231lbs) (approx) Varies

Suitable Applications

Dew-point calibrations in metrology laboratories