国产精品三级-日韩中文字幕在线播放-欧美色图88-爱福利视频网-美女视频黄免费-青青草视频在线观看免费-国产主播一区二区-久久理论电影-污污网站在线-国产精品12-99精品在线观看视频-丁香啪啪-国产成人精品免高潮在线观看-日韩高清在线一区-久久久久毛片-91精品国产91久久久久久-美女扒开腿让男生桶-91性生活-91黑丝美女-91大神久久

Products

current position:home page>Products>Measuring Instrument>Campbell>

CS100 Barometric Pressure Sensor

Updated:2025-03-13

Views:1002

  • Brand: Campbell
  • Model: CS100
  • Description: The CS100 measures barometric pressure for the range of 600 to 1100 hPa (mBar). This range equates to from below sea level (as in a mine) up to 12,000 feet above sea level. Designed for use in environ
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

CS100 Barometric Pressure Sensor Description:

Product Manual Datasheet

The CS100 measures barometric pressure for the range of 600 to 1100 hPa (mBar). This range equates to from below sea level (as in a mine) up to 12,000 feet above sea level. Designed for use in environmental applications, the CS100 is compatible with all Campbell Scientific data loggers.

Detailed Description

The CS100 is a Campbell Scientific version of Setra's model 278 barometer. It uses Setra’s Setraceram capacitive sensor and IC analog circuit to measure barometric pressure. The CS100 iincludes a 0.76 m (2.5 ft) cable and a terminal strip for data logger power and signal connections.

The CS100 is encased in a stainless-steel and polyester case fitted with an 1/8 in. barbed fitting for pressure connection. It includes an internal switching circuit that allows the data logger to power the barometer only during measurement, which reduces power usage.

Benefits and Features

Optimized to mount in Campbell Scientific enclosures

Low power consumption

Three-year warranty

Integral switching circuit limits power consumption to measurement cycle

CS100 Barometric Pressure Sensor Specifications:

Measurement Description Barometric pressure
Signal Type/Output Analog voltage
-NOTE- 1 hPa = 1 mBar
Pressure Range 600 to 1100 hPa
Long-Term Stability ±0.1 hPa per year
Response Time < 100 ms
Resolution ±0.01 hPa
Excitation 9.5 to 28 Vdc
Elevation ~609.6 m (2,000 ft) below sea level (as in a mine) to 3,657.6 m (12,000 ft) above sea level
Accuracy
  • Accuracy refers to the root sum squared (RSS) of end point non-linearity, hysteresis, repeatability, and calibration uncertainty.
  • ±0.5 hPa (@ +20°C)
  • ±1.0 hPa (@ 0° to 40°C)
  • ±1.5 hPa (@ -20° to +50°C)
  • ±2.0 hPa (@ -40° to +60°C)
Linearity ±0.4 hPa
Hysteresis ±0.05 hPa
Repeatability ±0.03 hPa
Signal Output 0 to 2.5 Vdc
Warm-up Time < 1 s
External Trigger Voltage
  • 0 Vdc (sleep mode)
  • 3 to 28 Vdc (operating mode)
Current Consumption
  • < 3 mA (active)
  • < 1 μΑ (sleep mode)
Temperature Range -40° to +60°C
Cable Diameter 0.8 cm (0.3 in.)
Cable Length 0.8 m (2.5 ft)
Dimensions 9.1 x 6.1 x 2.5 cm (3.6 x 2.4 x 1.0 in.)
Weight 135 g (4.8 oz)

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com